Use this free generator installation cost calculator to estimate what installing a home generator costs, from a portable unit with an inlet box to a permanent whole-house standby system that starts itself. Pick your generator type and size, choose your fuel and transfer equipment, and set the gas line distance. You will get a planning estimate split into generator equipment, transfer switch, gas work, pad and permit costs, with budget, standard and premium levels to compare before you call an installer.

Estimate My Generator Cost

Generator Installation Cost Calculator

Generator cost depends on the route you choose. A portable generator with an inlet box and interlock kit is a small electrical job. A standby whole-house system is a multi-trade project: the generator, an automatic transfer switch, a gas line, a pad, permits and a full test under load. That is why quotes for backup power can run from under $2,000 to well over $15,000.

Pick your generator type, size and fuel, set the transfer equipment, gas line distance and pad, then tick any extras such as a permit allowance, a load shedding module, trenching or surge protection. Then enter your ZIP code so we can match you with local professionals if you want a firm quote. This estimate uses national planning averages, not ZIP-specific pricing.

Get Your Free Estimate

Complete the form below to get matched with local electricians for your generator installation.

OmniEstimate – Universal Calculator Quote Request

How to Read Your Results

Your result shows one headline planning estimate for a standard project, plus a typical range from the Budget total to the Premium total.

Below that you will see three cards. Budget assumes a basic generator and a lower labor rate. Standard assumes a quality generator, a licensed electrician and typical access. Premium assumes a premium generator, a specialist crew and difficult access. The breakdown shows materials, labor and other costs for the standard project, with a line-item table listing quantity, rate and subtotal for every line. Labor hours grow with generator size, with the gas line distance, and in older homes where the panel often needs attention first.

Cost Breakdown Explanation

Materials cover the generator itself, the transfer switch or interlock equipment, breakers, conduit and wire, and gas line pipe and fittings priced per foot of run. Bigger generators cost more and need larger gas lines. Labor covers the electrician and gas fitter time to set the unit, connect power and fuel, and test under load, adjusted for home age. Other costs can include a concrete or composite pad, a load shedding module, trenching and surface restoration, whole-house surge protection, and a permit and inspection allowance. Each extra is priced only when you tick it.

generator installation cost calculator - cost by installation scenario diagram

Quick Answers

How much does a whole-house generator cost installed?
Published 2026 US figures put a whole-house standby system at $8,000 to $16,000 installed (Generac), or $6,000 to $11,000 on HomeGuide’s cost data, with most 18 to 22 kW jobs landing at $10,000 to $15,000. The generator itself is roughly a third to a half of the total. Use the generator installation cost calculator above for a figure based on your size and fuel.

How much does a portable generator hookup cost?
An inlet box with an interlock kit typically costs about $400 to $850 installed, and a manual transfer switch setup about $400 to $1,300, before the portable generator itself. A good 10 kW portable unit adds roughly $950 to $1,900. This route powers selected circuits and relies on you to start and connect the unit during an outage.

What size generator do I need for my house?
Most homes that want whole-house backup with one central air conditioner land at 18 to 22 kW, which is why 22 kW is the best-selling standby size. A load calculation, not square footage alone, sets the right size. Load shedding modules let a smaller unit carry a home by dropping big loads like air conditioning when other loads run.

Do I need a permit to install a generator?
In most areas, yes. A standby install usually needs an electrical permit and a gas permit, plus inspections, and many utilities must be notified. Fees vary by city and county. This calculator includes a permit and inspection allowance only if you tick it.

How Much Does Generator Installation Cost?

There is no single price for generator installation, because the total depends on the route you pick: portable with an inlet box, or permanent standby. A 10 kW portable on an interlock kit and a 26 kW diesel standby unit on a trenched gas line are both called generator installs, but they are priced very differently.

Published 2026 US figures put a whole-house standby system at $8,000 to $16,000 installed on Generac’s published range, or $6,000 to $11,000 on HomeGuide’s cost data, with large or complex jobs over 20 kW running $9,500 to $24,000. A 22 kW unit lists at about $6,100 alone, or about $7,000 with a 200-amp automatic transfer switch. Installation labor typically runs $1,500 to $5,000, the transfer switch $800 to $2,000 installed, and a concrete pad $400 to $1,200. That spread is exactly what this generator installation cost calculator is built to untangle.

The table at the end of this article shows four example projects calculated by this tool. Use them as reference points, then run your own numbers in the calculator above.

How This Calculator Works

The calculator builds your estimate from the same pieces an installer would price. It uses planning assumptions rather than live contractor data. Your ZIP code is used only to match you with local professionals and does not change the price.

Generator type and size: portable units are priced from 7.5 to 26 kW with an inlet box and interlock or manual transfer equipment. Standby units are priced across the same sizes, with 18 to 22 kW covering most whole-house jobs. Bigger units cost more and need heavier wire and larger gas lines.

Fuel: natural gas units tie into your existing gas service and never need refilling, but make slightly less power than their nameplate. Propane needs a tank, which is not priced here. Diesel standby units cost more and suit larger or off-grid homes.

Transfer equipment: a manual interlock or switch is the budget route and you operate it yourself. An automatic transfer switch senses the outage, starts the generator and transfers the load with no action from you, and costs more in parts and labor.

Gas line and pad: standby gas line materials are priced per foot of run, and labor hours rise with distance. A concrete pad costs more than a composite or gravel pad but lasts longer and suits larger units.

Extras: a permit allowance, a load shedding module, trenching and surge protection are each added only when selected, with their own materials, equipment and labor lines.

Levels: Budget, Standard and Premium use different generator grades and labor rates ($85, $110 and $145 per hour in this tool). They are not one number multiplied by a percentage.

What Drives the Cost of Generator Installation

Generator size: every step up in kW adds unit cost, and 26 kW units need larger gas lines and pads than 18 kW units.

Portable vs standby: an inlet and interlock is a few hundred dollars of electrical work; a standby system adds the transfer switch, gas work, pad and testing.

Transfer switch: automatic whole-house switches cost far more than a manual interlock, in both parts and installation time.

Gas line distance: every foot is pipe, fittings and labor, and long runs may need trenching or a larger gas meter.

Fuel setup: propane tanks, regulators and diesel storage are separate costs that installers often quote apart from the generator.

Permits and inspections: electrical and gas permits, utility notification and inspection visits all add fees and scheduling time.

Materials vs Labor

The generator itself is the biggest single line, roughly a third to a half of a standby total in published guides. A 22 kW unit lists at about $6,100, or about $7,000 bundled with a 200-amp automatic transfer switch. The rest is labor and site work: setting and leveling the unit, running gas and electrical lines, landing the transfer switch at the panel, and testing the system under a simulated outage. Published labor figures run $1,500 to $5,000 for a typical install and higher for long runs. That is why this generator installation cost calculator prices the gas run per foot and labor by the hour instead of quoting one flat number.

generator installation cost calculator - wiring an automatic transfer switch beside the electrical panel

Permits and Inspections

A standby generator install normally needs an electrical permit and a gas permit, an inspection of both, and in many areas a utility notification before the transfer switch is energized. Setback rules also apply: most codes require clearances from windows, doors and property lines, and carbon monoxide placement rules are strict. Portable hookups need an electrical permit in most areas too, and the interlock kit must be listed for your exact panel. The calculator includes a permit and inspection allowance only if you tick it.

Common Types of Generator Installation Jobs

Portable generator with inlet box and interlock kit for essential circuits.

Whole-house standby on natural gas with an automatic transfer switch.

Standby on propane with a buried or above-ground tank for rural homes.

Larger 24 to 26 kW standby for homes with two air conditioners or a pool.

Standby with load shedding so a smaller unit can carry a larger home.

generator installation cost calculator - trenching a gas line to a standby generator

Repair, Replace or Upgrade?

Start with a load calculation, not a guess. If outages are short and you only need the fridge, lights and furnace fan, a portable with an inlet and interlock does the job for a fraction of standby cost. If you need automatic backup for medical equipment, a sump pump or air conditioning, standby is the right route. Sizing down helps too: a load shedding module (often $300 to $700) lets an 18 kW unit carry a home that would otherwise need 22 kW, by pausing big loads when others run. Ask any installer quoting you whether the pad, gas line, permits, propane tank and first service are included, since those lines explain most of the gap between quotes. Running the same job through this generator installation cost calculator first gives you a checklist to compare those quotes against.

Budget, Standard and Premium Projects

A budget project uses a basic generator and a lower labor rate. A standard project uses a quality generator, a licensed electrician and typical access. A premium project uses a premium generator, a specialist crew and difficult access. The three levels use different generator prices and different hourly labor rates. They are not the same number scaled by a percentage. Pick the level that matches the generator and installer you actually want, not just your budget.

Regional Pricing Differences

Electrician and gas fitter rates vary across the United States. Dense metro areas and regions with high licensing costs generally cost more than smaller markets, and permit fees vary by city and county. This calculator uses national planning averages and does not adjust the price by ZIP code, so treat the result as a starting budget and compare it with local written quotes for your generator install.

Example Projects Calculated by This Tool

Project 1 – Standby 22 kW natural gas, typical whole-house

Standby whole-house, 22 kW, natural gas, automatic transfer switch, 25 ft gas line, concrete pad, home built 1970-1999, permit allowance included. Standard labor about 17.3 hours. Budget $7,000 – $8,800. Standard $9,400 – $11,700 (headline $10,500). Premium $13,100 – $16,400.

Project 2 – Portable 10 kW with inlet and interlock

Portable generator, 10 kW, propane, manual interlock equipment, no pad, built 2000 or later, permit allowance included. Standard labor about 3.0 hours. Budget $1,450 – $1,800. Standard $2,150 – $2,650 (headline $2,350). Premium $3,300 – $4,100.

Project 3 – Standby 18 kW propane with load shedding

Standby whole-house, 18 kW, propane, automatic transfer switch, 40 ft gas line, composite pad, built before 1970, permit and load shedding module included. Standard labor about 20.3 hours plus 1 hour for the module. Budget $6,800 – $8,500. Standard $9,100 – $11,300 (headline $10,100). Premium $12,800 – $16,000.

Project 4 – Standby 26 kW diesel with trenching, older home

Standby whole-house, 26 kW, diesel, automatic transfer switch, 60 ft gas line, concrete pad, built before 1970, permit, trenching and surge protection included. Standard labor about 26.0 hours. Budget $10,100 – $12,600. Standard $13,700 – $17,000 (headline $15,200). Premium $19,200 – $23,900.

Generator Installation Cost FAQs

How much does a whole-house generator cost installed?

Published 2026 US figures put a whole-house standby system at $8,000 to $16,000 installed on Generac's published range, or $6,000 to $11,000 on HomeGuide's cost data, with most 18 to 22 kW jobs landing at $10,000 to $15,000. Large or complex jobs over 20 kW run $9,500 to $24,000. Run this calculator with your size and gas distance for a planning range.

An inlet box with an interlock kit typically costs about $400 to $850 installed, and a manual transfer switch setup about $400 to $1,300, before the portable generator itself. The inlet box part alone is only about $20 to $150; most of the bill is the breaker, wiring, interlock and labor.

Square footage alone does not set the size; the load does. Most 2,000 square foot homes with one central air conditioner land at 18 to 22 kW for whole-house backup. A load calculation by the installer confirms it, and load shedding can let a smaller unit carry the same home.

Natural gas never needs refilling and suits homes with utility gas, but output drops slightly versus the nameplate. Propane stores well and suits rural homes, but needs a tank sized for long outages. Diesel standby units cost more, last longer under heavy use, and suit larger or off-grid homes.

Both stop your generator from backfeeding the grid, which is illegal and dangerous. An interlock kit is a sliding plate on your panel that you operate by hand and costs less. A transfer switch, manual or automatic, is separate equipment; automatic models start the generator and switch the load with no action from you.

Codes set minimum clearances from windows, doors and vents for carbon monoxide safety, commonly at least 5 feet from openings, and the gas line must be sized for the run. Longer runs cost more in pipe, fittings and labor, and very long runs may need a larger gas meter. This calculator prices the gas run per foot.

In most areas, yes. A standby install normally requires an electrical permit and a gas permit, inspections of both, and often utility notification. Portable inlet hookups need an electrical permit in most areas too. Fees vary by city and county, so this calculator includes a permit and inspection allowance only if you select it.

A permanently installed standby system is a selling feature in outage-prone areas and is usually listed with the home, unlike a portable. Appraisers vary on the exact value added, so treat it as resilience and convenience first, and any resale benefit as a bonus rather than a guaranteed return.

Ready to Plan Your Generator Installation?

Compare your planning estimate with written quotes from licensed local electricians before you commit to a budget.

This calculator provides a planning estimate only. It is not a quote, bid or guaranteed price. Actual contractor pricing may vary based on location, conditions, material choice, labor market and project complexity. Always obtain written, itemized quotes from licensed and insured professionals before committing to a budget.

Find a Top-Rated Pro by City